Modernization of the central heating system of the steam turbine K-1000-60/3000 of power unit No. 2 branch of the Khmelnytskyi NPP
Sector
Energy Sector
Stream
Modernization/renovation of installed generating capacities
Project Status
Preliminary Investment Feasibility Study
Entry into Portfolio
State Single Project Pipeline
Investment Feasibility Study
Implementation
Completion
- Підготовка
- Загальний опис
- Стратегічне обґрунтування
- Економічне обґрунтування
- Комерційне обґрунтування
- Фінансове обґрунтування
- Управлінське обґрунтування
General information
Description of the project
The project involves replacing the CVT rotor with a new one, which will provide the ability to carry increased power due to improved technical characteristics and will be installed in the existing CVT outer casing without changing the thermal scheme. Due to the modernization of the CVT rotor, the power of power unit No. 2 of KhNPP will increase.
The purpose of the project
Main goal:
Capacity building
Secondary goal:
Improving the condition of infrastructure
Description of the purpose of the project and ways to achieve it
The project involves the replacement of the CVT rotor with a new one, which will provide the possibility of carrying increased power due to improved technical characteristics and will be installed in the existing external case of the CVT without changing the thermal circuit. Due to the modernization of the CVT rotor, the capacity of power unit No. 2 of the Khao NPP will be increased.
Problems and solutions resulting from project implementation
Increasing the capacity of operating NPP power units is an effective way to obtain additional generating capacity. The project involves replacing the CVT rotor with a new one, which will provide the ability to carry increased power due to improved technical characteristics and will be installed in the existing CVT outer casing without changing the thermal scheme. Due to the modernization of the CVT rotor, the capacity of power unit No. 2 of KhNPP will increase.
Strategic Case
Strategic feasibility of the project
Sector
Energy Sector
Subsector
Electric power industry
Stream
Modernization/renovation of installed generating capacities
Strategic document
Energy Strategy of Ukraine until 2050
Task
null Implementation of measures to repair and modernize energy infrastructure
Project objectives
Indicator
Base value
Target value
power
830 MW
1040 MW
Demand for the service and its dynamics
Indicator
Year
Demand
Annual demand for services/infrastructure
1
103000 kWh
Economic justification
Alternative technical solutions
Technical Solution 1
Modernization (1 unit) of the K-1000-60/3000 central heating system
Total costs729'270'002 UAH
Average annual costs1 UAH0
Project duration, incl.389 months0 months
Target indicatorsDefined
Financial justification
Total project budget
Total preliminary budget729'270'002 UAH
Capital costs729'270'002 UAH
Operational costs0 UAH
Preliminary cost breakdown
Operating costs for implementation0 UAH
For preparation12'000'000 UAH
For implementation717'270'000 UAH
For operation1 UAH
For closing1 UAH
Average project cost per service recipient
Service Unitод
Service Unit Cost1 UAH
Profitability of the project
Is the project expected to generate income?
ResponseNo
spi.projectFinancingMechanisms.title
spi.projectFinancingMechanisms.subtitle
spi.projectFinancingMechanisms.rowTitleYes
Management Rationale
Risk assessment
Financial riskDefined