General information
Description of the project
It is planned to install a line for the production of pellets from waste from forestry, agricultural and other activities of enterprises in the district.
The purpose of the project
Main Goal:
Improving the quality of services
Secondary Goal:
Improving the condition of infrastructure, Introducing innovations and energy-efficient solutions
Description of the purpose of the project and ways to achieve it
The project aims to produce thermal energy through the use of cheap biofuel of its own production from wood waste after cleaning urban and forest plantations and crop residues.
Problems and solutions resulting from project implementation
The installed solid fuel boiler KVr (KV) - 2.0 has insufficient capacity to fully provide heat supply services in the event of gas supply outages. The city's municipal services supply the KP ".Teplokomunenergo" with wood waste after sanitary cleaning of urban and forest plantations. There is an opportunity to obtain inexpensive crop residues in the community's farms. The pellet production line will allow the adaptation of raw materials for the needs of the enterprise.
Socio-economic context
Indicator
Value
Number of people who will use the service
6200 human
Strategic Case
Strategic feasibility of the project
Sector
Municipal infrastructure and services
Subsector
Urban planning and landscaping
Stream
Improving energy efficiency in public buildings
Strategic document
Стратегія розвитку територіальної громади
Task
3.3.2 Improving the energy efficiency of existing facilities in the community and introducing alternative energy sources
Project objectives
Project objectives were not specified by the initiator
Demand for the service and its dynamics
Indicator
Year
Demand
Annual demand for services/infrastructure
1
60 t
Economic justification
Alternative technical solutions
Technical Solution 1
Installation of a fuel pellet production line and a solid fuel water heating boiler
Technical Solution 2
Installation of a solid fuel water heating boiler
Cost breakdownCost justificationCost justification
Project cost (preparation and implementation)12'500'000 UAH12'500'000 UAH
For preparation500'000 UAH500'000 UAH
For implementation12'000'000 UAH12'000'000 UAH
Project operation and closure cost1'500'000 UAH700'000 UAH
For operation1'200'000 UAH500'000 UAH
For closing300'000 UAH200'000 UAH
Average annual costs2'000'000 UAH0 UAH
Project duration, incl.36 months20 months
Deadline for developing a FFS8 months4 months
Implementation period28 months16 months
Service life240 months240 months
Target indicatorsDefined Defined
Technical Solution Status
Active
[The technical approach was selected for further detailed analysis or implementation.]
Rejected
[The technical approach was not selected for further detailed analysis or implementation.]
Components of a technical solution
Financial justification
Total project budget
Total preliminary budget14'000'000 UAH13'200'000 UAH
Project cost (preparation and implementation)12'500'000 UAH12'500'000 UAH
For preparation500'000 UAH500'000 UAH
For implementation12'000'000 UAH12'000'000 UAH
Project operation and closure cost1'500'000 UAH700'000 UAH
For operation1'200'000 UAH500'000 UAH
For closing300'000 UAH200'000 UAH
Average project cost per service recipient
Service UnitГкал
Service Unit Cost3'850 UAH
Profitability of the project
Is the project expected to generate income?NoNo
Project Financing Mechanisms
Are funding sources and mechanisms identified?
Source and MechanismYesNo
Funding Sources
Approved Funds0 UAH0 UAH
Expected Funds0 UAH0 UAH
Management Rationale
Risk assessment
Financial riskDefinedUndefined
Project Approval History
DateDecision NumberPortfolioProject StatusDecisionReasonsMaturity level
02/10/2025SP-L-021025-0E701630Community SPInvestment Feasibility StudyInclude--
25/03/2026SP-N-250326-FFD378EEState SPInvestment Feasibility StudyAwaiting reviewThe project corresponds to the direction "Rehabilitation, modernization and development of centralized and decentralized heating systems" and should be redirected to the appropriate sectoral portfolio-
21/10/2025SPP-L-211025-7F847E2DCommunity SPPInvestment Feasibility StudyInclude-88